Episodios

  • See Full Video episode -> https://youtu.be/0fJ3uSAQwLg
    In this episode, Robert and Reggie speak with Kelly Mantooth, an MR Safety expert, about RF burns in MRI. They discuss the definition of RF burns, how they differ from overall heating (SAR), the four types of burns (proximity, looping, resonant, and reflective), statistics on RF burns, causes, preventative measures, treatment, and personal experiences. Key points include: RF burns are caused by local/focal heating rather than overall heating, positioning and proper padding are crucial for prevention, certain sequences don't necessarily increase burn risk, and identifying high-risk patients is important. Kelly shares stories from her career that influenced her passion for MR safety.

  • See Full Video episode -> https://youtu.be/wFBwmt74wHo?si=s_XFJytnI6dWn2Kr
    In this episode of Zone 3 Podcast, Reggie and Robert discuss training new MRI technologists. Rob Cloutier, a well-known MRI Educator, discusses his approach to training technologists, focusing on understanding the 'why' behind MRI instead of just memorizing protocols. He talks about the importance of teaching MRI concepts in simple, easy-to-understand ways using analogies and stories. The key takeaways are to focus on the fundamentals like coverage, angles, phase direction, and assessing for motion and wrap. Rob emphasizes empowering technologists to think critically instead of being 'button pushers' who blindly follow protocols. He shares real examples of problem-solving on cases and talks about the importance of communication, efficiency, and attention to detail in producing quality diagnostic images.

  • ¿Faltan episodios?

    Pulsa aquí para actualizar resultados

  • See Full Video Episode --> Revolutionizing MRI with Remote Scanning & Alpha RT | https://youtu.be/NV9u6O-Xr4I

    The podcast features Pete, Neil, Ryan, and Dr. Rekhi from Alpha RT.
    Alpha RT focuses on remote scanning in the MRI field and plans to expand cautiously while maintaining exceptional service quality and safety.- They emphasize the importance of safety and have developed an MRI Tech Aid program to train tech aids. The program includes a 9-week curriculum covering personnel safety, medical terminology, equipment, anatomy, and codes.- The clinical training includes supervised on-site experience and a certification exam.- Alpha RT's approach prioritizes safety and solving staffing shortages while providing innovative solutions in the industry.

    The Future of Radiology: Explore how remote scanning is revolutionizing patient care and safety in radiology.
    Expert Insights: Hear from the co-founder of a pioneering remote scanning company, a VP of Partnerships, a day-to-day operations specialist, and a practicing radiologist.
    Challenges & Solutions: Learn about the hurdles in implementing remote scanning, from safety protocols to staffing challenges, and how these are being innovatively addressed.
    Educational Aspects: Discover the intricacies of our MRI Tech Program that's setting new standards in the field.
    Safety First: Understand the stringent safety measures and patient care protocols in place.
    Looking Ahead: Get a glimpse into the future goals and aspirations in remote scanning technology.
    šŸ¤ Join us in this enlightening journey as we uncover how technology and expertise come together to transform radiology. Don't forget to like, share, and subscribe for more content from Zone 3 Podcast!

    #Zone3Podcast #RemoteScanning #RadiologyRevolution

    ALPHA RT website - https://remotemriscanning.com/

  • Watch Episode at Pros and Cons of Field Strengths: 1.5T vs 3T vs 7T https://youtu.be/whvW8CZU7Ss

    Dive into the nuances of MRI field strengths as we discuss the pros and cons of 1.5T, 3T, and 7T with our special guest, Jesse Bashford. Learn about protocol optimization, the importance of equipment, and the ideal scenarios for each field strength.

    Also Check out New and Improved Padding - https://mrpadwell.com/

  • Watch Episode --> https://youtu.be/N1UYoQPNzUI

    Join us in this enlightening episode of the Zone 3 Podcast as we delve deep into the world of MRI parameters with our guest expert, Matt Rederer, To find out what we really are doing when change certain parameters. This video is a comprehensive guide to understanding and optimizing MRI parameters for the best image quality

    Video Chapters:
    Introduction [0:00 - 1:00]
    Opening of the topic and the guest, Matt.

    Understanding TR (Repetition Time) [1:01 - 10:00]
    Explanation of TR and its impact on T1 contrast in the image.
    Discuss the importance of finding the "sweet spot" for TR to achieve the best image quality.

    Understanding TE (Echo Time) [10:01 - 20:00]
    Explanation of TE and its role in controlling T2 contrast.
    Discussion on how a higher TE will result in more signal loss, affecting the contrast.

    Understanding TI (Inversion Time) [20:01 - 30:00]
    Explanation of TI and its role in an inversion recovery sequence.
    Discussion on how TI is used to nullify the signal from certain tissues, enhancing the contrast between different tissues.

    Understanding ETL (Echo Train Length) [30:01 - 40:00]
    Explanation of ETL and its role in a fast spin echo sequence.
    Discussion on how a longer ETL can speed up the scan but may also result in more image blurring.

    Understanding Flip Angle [40:01 - 50:00]
    Explanation of the flip angle and its role in MRI.
    Discussion on how the flip angle can affect the contrast and signal-to-noise ratio of the image.

    Understanding Diffusion Weighted Imaging [50:01 - 60:00]
    Discussion on the role of the B value in diffusion-weighted imaging.
    Explanation of how a higher B value will result in more diffusion weighting, but also more noise in the image.

    Understanding Phase Contrast Imaging [60:01 - 70:00]
    Discussion on the role of the VENC (Velocity Encoding) value in phase contrast imaging.
    Explanation of how the VENC value needs to be adjusted based on the velocity of the flow being imaged to avoid aliasing artifacts.

    Conclusion [70:01 - End]
    Recap of the main points discussed in the video.
    Closing remarks and end of the video.

    This video covers key MRI parameters including TR, TE, TI, ETL, and Flip Angle. We also delve into the intricacies of Diffusion Weighted Imaging and Phase Contrast Imaging.

    Whether you're an MRI professional or a student in the field, this video is a valuable resource for enhancing your understanding of MRI parameters and their impact on image quality.

    Connect with us:
    For more informative videos on MRI and related topics, subscribe to our channel and turn on notifications. Don't forget to like and share this video if you found it helpful.


    About our Guest:
    Matt is the President of RITE Advantage LLC. A company focused on educating and testing MRI, CT, Sonography, and Radiography students and technologists. The lead MRI technologist and a certified MR Safety Officer at Advocate Sherman Hospital. Matt is also the MRI/CT Physics Professor at Elgin Community College.

    Mattā€™s very knowledgeable at MRI physics which is the fundamental factor for image acquisition. So in addition to tricks and tips learned from coworkers, Matt stresses the importance of understanding how to optimize the image youā€™re acquiring by means of physics. Matt appreciates the artistic influence that naturally comes with photography. If you understand whatā€™s happening on the back end in terms of k space etc., then you can be the creator of new tips and tricks to share with your coworkers and team.

  • Watch now on Youtube --> Shaking Things up with MR Elastrography https://youtu.be/IfkjM96BD80

    Another fun episode with another fun guest. Kay Pepin PhD is the Vice President, Research & Global Collaboration Resoundant and a Senior Engineer in the Advanced Imaging Lab at Mayo Clinic led by Dr. Richard Ehman. She specializes in the use of imaging in liver disease. Dr. Pepin has a background in technique development, translational research, education, and collaboration management and is an expert on the development and implementation of Magnetic Resonance Elastography (MRE).

    Magnetic resonance elastography (MRE) of the liver has emerged as the non-invasive standard for the evaluation of liver fibrosis in chronic liver diseases (CLDs). The utility of MRE in the evaluation of different CLD in both adults and children has been demonstrated in several studies, and MRE has been recommended by several clinical societies. Consequently, the clinical indications for evaluation of CLD with MRE have increased, and MRE is currently used as an add-on test during routine liver MRI studies or as a standalone test. To meet the increasing clinical demand, MRE is being installed in many academic and private practice imaging centers.

    Dr. Pepin talks about proper positioning of the elastography paddle. Prescribing of sequences. How to QA images to ensure an adequate study. How to trouble shoot different challenges that inherently arise with such a new and advanced method of imaging. She covers the pathologies that are best demonstrated. Clinical indications and imaging contraindications. A variety of Magnet manufactures have upgraded their existing units to accommodate the installation of MRE equipment. Dr. Pepin covers what those requirements are and helps to illustrate the simplicity.

    The origin story is fascinating. Listen along and take note of the complexities and how beneficial MRE can be for a growing population who suffer the clinical indications. It was a joy to have Dr. Kay Pepin on. Sheā€™s a natural in front of the camera which makes for entertaining and easy viewing.

  • Check out the Video --> GE Healthcare Revolutionary AIRā„¢ Coils and AIRā„¢ Recon DL | https://youtu.be/MbT_fTqL_oE

    Join Reggie and Robert in this exciting episode of Zone3Podcast as they sit down with Bradley Tomlinson, GE Healthcare's Rocky Mountain Region Manager of MR operations. Listen as Brad shares his inspiring career journey and introduces the hosts to GE's award-winning AIRā„¢ Coils, an industry first in MRI coil design. The trio discusses the benefits of these ultra-light, flexible, and overlapping coil elements that deliver the exceptional image quality and a simplified, faster workflow.

    But that's not all! Brad also dives into the game-changing AIRā„¢ Recon DL algorithm, which transforms the MRI image reconstruction process. With its ability to perform ringing suppression and SNR improvement, AIRā„¢ Recon DL offers clinical, operational, and financial benefits over conventional image reconstruction, including sharper images, reduced scan time, greater tolerance of protocol variations, and easier-to-read images.

    Listen to this informative episode to learn about the latest advancements in MRI technology and how the AIRā„¢ Coils and AIRā„¢ Recon DL are changing the game for clinicians, patients, and the industry. Don't miss out on this exciting episode of Zone 3 Podcast!

    GE AIR Technology - https://www.gehealthcare.com/products...

  • Video Link --> https://youtu.be/hgnq4zy1ivE

    Zone3Podcast and the gang happy to be joined by Dr. Joanna Shechtel, MD. Dr Shechtel earned her medical degree from Georgetown University. She completed a residency in Diagnostic Radiology at University of Tennessee - Knoxville, where she served as Chief Resident, and a fellowship in Musculoskeletal Imaging at Vanderbilt University Medical Center (VUMC). In 2021, Dr. Shechtel joined VUMC faculty as an Assistant Professor of Clinical Radiology in the Musculoskeletal Radiology section. She is a member of the Radiological Society of North America, American Roentgen Ray Society, American College of Radiology, Tennessee Medical Association and Nashville Academy of Medicine. Dr. Shechtel's clinical interests include MRI safety, quality improvement and resident education.

    Dr. Shechtel main area of expertise is sarcomas as it pertains to MSK Diagnostic Imaging. Sarcomas are rare cancers that develop in the bones and soft tissues, including fat, muscles, blood vessels, nerves, deep skin tissues and fibrous tissues. There are many risk factors for sarcomas. History of radiation therapy, genetic predisposition and chemical exposure. Imaging properties include size, adjacent tissue differences, infiltrating and contrast enhancement.

    She was first introduced to the importance of MRI safety by Dr. Peter Petruzzi, MRMD during her residency. She credits Dr. Shellock for her choice to later become a board member of ABMRS.

    Many factors to consider for sarcoma imaging. coils, image planes, patient positioning, FOV, phase direction, technique, sequence selection etc. Dr. Shechtel doesnā€™t have a preference in field strength if imaging quality isnā€™t compromised. Duplicating a prior study is also a consideration and should be the goal absent of contraindication. High resolution imaging is her preference over small FOV imaging if forced to decide between the two. She stresses the importance of Surgeon preference consideration with joint-to-joint imaging. Prothesis may be in that patientā€™s course of care. Large FOV imaging allows for pre-op measurements as well as visualization of skip lesions.

    We always love it when our guests come prepared with helpful visual aids. Dr. Shechtel brings imaging examples which help illustrate her case in point. It was a joy spending with someone of Dr. Shechtelā€™s caliber.

  • See full video Episode --> What does a Field Service Engineer do? or https://youtu.be/loS_vEyMc2o

    Another great Zone3Podcast episode with Field Service Engineer Todd Beaudoin. Todd is originally from North Dakota. Relocating to Arizona to pursue a Bachelor of Science and Electronic Engineering at DeVry University. Starting in the semiconductor industry for the first several years of his career. To when he eventually transitioned into healthcare. He started his training with Fomar MRI manufacturer. There he worked directly with Dr. Raymond Damadian credited as the inventor of Magnetic Resonance Imaging. That very unique experience gave him advanced knowledge of image acquisition which he uses daily to help identify scanner equipment issues.

    After that training, he then worked with GE Healthcare for 13 years. Currently, he works for the Mayo Clinic servicing multi-modality equipment, but mostly his time is spent on MRI. Providing multi-vendor service. Dealing with mechanical problems, environmental controls, electronics, electricity, networking problems, etc. Todd encourages anyone interested in the field to pursue it. Itā€™s a great time considering employers offer incentives such as putting you through school to obtain your degree.

    Todd discusses his day-to-day operations describing the majority of his time spent is reactive in nature. Responding to issues as they arise. Usually reported to him and his department directly from the technologists that operate the scanner. Remote access allows him the ability to diagnose the problem but he prefers to be more hands-on. In addition to unplanned unexpected issues, preventive maintenance also is not only necessary but valuable to stop problems before it happens. Todd describes one of his biggest hurdles to overcome is scanner time. The department allows him the time to investigate, identify, and fix any problems when they happen. Error logs are the most helpful starting point. Some issues are quick fixes. However, some problems can keep Todd and other technicians in the department there through the night. Something as simple as calibration can take up to 4 hours. Software/hardware upgrades present their own sets of challenges.

    Todd expresses the importance of Daily/weekly QA. That data trends the machine, any deviation is usually indicative of a current or upcoming cause for concern. A proactive way to maintain the machine. The logistics of maintaining the temperature of the magnet and scanner environment.

    Todd is an absolute genius as are all Field Service Engineers. He credits his training and the people heā€™s surrounded with. Collectively his team is able to quickly identify a problem and fix it. Downtime translates to a lack of patient care. The sooner he and his team can get it up and running again the sooner the technologist can provide care to that next patient.

    About our Sponsor:
    Aegys is an innovative leader in the MRI safety industry and the Creator of The TechGate Automatic.
    Aegys is committed to providing innovative product and process solutions that enhance overall magnet safety and improve efficiency. TechGate Auto is a Zone 4 Barrier System that keeps patients and MRI technologists safe. TechGate Auto allows technologists to focus on the care of patients and efficient room turnaround rather than worrying about anyone entering the MRI room behind them. Easy to use and designed for the MRI environment, TechGate Auto is deployed whenever the technologist enters or leaves the MR room or via push button remote control, providing an immediate physical restriction of access to all unauthorized individuals.

    The use of a ā€œcautionā€ barrier at the entrance to the MR room is now a recommendation of the American College of Radiology MR Safety Committee.


    Links
    Aegys' Tech Gate Auto- https://aegysgroup.com/

    ----------
    Imaging Diversified

    Imaging Diversified was established in 2019 with the aspiration of offering onsite training to his peers through vendors that sell MRI and CT equipment. He received subpar training on more than one occasion after new MRI installations. With the goal to remedy this, he started being more active in sharing his knowledge on scanner utilization starting in 2011 after attending a conference by Dr. Kanal. Over years he was exposed to different vendors and learned the systems to become a superuser. He then shared that knowledge with his peers. This passion later became a business that welcomes application specialists and knowledgeable users that want to share their expertise and get paid to do it.

    Links:
    Email: [email protected]
    Website: www.imagingdiversified.com
    Social Media: Imaging Diversified

  • In this episode of the Zone3 podcast, hosts Robert and Reggie sit down with Dr. Jokerst and Dr.
    Marcotte, a radiologist, and a cardiologist to discuss cardiac MRIs.

    Early in the episode, Dr. Jokerst and Dr. Marcotte introduce themselves, discuss their
    collaboration, and what makes them work well together. They also cover some of the differences
    between MRI, echocardiograms, and CT scans.

    The doctors also discuss common pathologies and risk factors. Dr. Jokerst explains the tools he
    uses to differentiate imaging and diagnosis. They also cover the advancement of computer
    technology and its effect on imaging.

    The episode wraps up with a conversation about physics and educational materials for
    technologists. They also highlight the collaboration between radiology and cardiology. Both Dr.
    Jokerst and Marcotte also share what inspires them in their work.

    00:53 - Dr. Jokerst and Dr. Marcotte dive into their background.
    4:40 - Robert and Reggie talk with the guests about imaging for
    17:36 - Dr. Marcotte discusses when a cardiac MRI may be necessary.
    28:17 - Robert and Reggie ask the doctors a hypothetical question about which machine they'd
    pick for their department.
    42:08- Robert and Reggie as their guests about common pathologies.
    1:19:41 The doctors discuss history and physics and educational materials.
    1:26:03 - Collaboration and building communication across disciplines.
    1:29:59 - Robert and Reggie ask the doctors about the most satisfying experiences in their field.

    Links:
    Learn more about the Society for Cardiovascular Magnetic Resonance
    Learn more about the Journal of Cardiovascular Magnetic Resonance

    Tags:
    radiology, CT, MRI, medical, hospital, doctor, radiologist, cardiologist

  • Video Episode --> Why Issues Addressed in the ACR's 2002 MRI Safety White Paper are still around today.

    While in town to attend AHRA 2022, returning guest Tobias Gilk joins Zone3podcast's Robert and Reggie in the Studio to discuss how the revisions made to the ACR white paper have made some progress but we still have a long way to go.

    Background:
    ACR assembled a group immediately following the Michael Colombini accident of 2001. In an effort to prevent further accidents ACR published a white paper on MR safety in 2002. The first document of its kind. A set of best practices guidance directing others to be more safety conscience. Toby also mentions how other countries came out with their version shortly after this.

    In 2004 it was revised and expanded upon. They then changed the name to the Guidance Document for Safe MR Practices. An additional update and expansion in 2007 and 2013. Then in 2020, The ACR self-published the documents as a manual.

    The purpose of continuous revisions is to stay current with MR safety in terms of devices/contraindications for what may be the new best practice.

    Toby helps explain ACR accreditation and the associated requirements. Benefits as well. And briefly touches on the requirements of the joint commission and how they compare to ACR recommendations.

    Lastly, Toby discusses how ACR could improve the MRI Safety Manual and where things may be headed.

    Thanks for joining us. Here in Zone 3. šŸ’Æ


    --Guest Links----
    Tobias Gilk Website - https://gilkradiologyconsultants.com/

    Zone 3 Podcast Website - Zone3Podcast.com

    ---Episode Content Link--
    2002 initial MRI Safety White paper - https://zone3podcast.com/wp-content/u...

    2013 ACR Guidance Document on MR Safe Practice https://zone3podcast.com/wp-content/u...

    2020 MRI Safety manual - https://www.acr.org/Clinical-Resource...

    --Other Episodes with Toby ----
    Episode: MRI Facility Design - https://youtu.be/ixL9rdZJihM
    Episode: Evolution of MRI Safety - https://youtu.be/UIMe9bgmS2U

    About our Sponsors:

    ---Aegy's TechGate Auto---
    Aegys is an innovative leader in the MRI safety industry and the Creator of The TechGate Automatic.
    Aegys is committed to providing innovative product and process solutions that enhance overall magnet safety and improve efficiency. TechGate Auto is a Zone 4 Barrier System that keeps patients and MRI technologists safe. TechGate Auto allows technologists to focus on the care of patients and efficient room turnaround rather than worrying about anyone entering the MRI room behind them. Easy to use and designed for the MRI environment, TechGate Auto is deployed whenever the technologist enters or leaves the MR room or via push button remote control, providing an immediate physical restriction of access to all unauthorized individuals.

    The use of a ā€œcautionā€ barrier at the entrance to the MR room is now a recommendation of the American College of Radiology MR Safety Committee.

    Links
    Aegys' Tech Gate Auto- https://aegysgroup.com/


    -----Imaging Diversified------

    Imaging Diversified was established in 2019 with the aspiration of offering onsite training to his peers through vendors that sell MRI and CT equipment. He received subpar training on more than one occasion after new MRI installations. With the goal to remedy this, he started being more active in sharing his knowledge on scanner utilization starting in 2011 after attending a conference by Dr. Kanal. Over years he was exposed to different vendors and learned the systems to become a superuser. He then shared that knowledge with his peers. This passion later became a business that welcomes application specialists and knowledgeable users that want to share their expertise and get paid to do it.

    Links: Youtube Channel
    Email: [email protected]
    Website: https://www.imagingdiversified.com/
    Social Media: #ImagingDiversified

  • See Video Episode Here ---> MR Angiography (MRA) Explained ---> https://youtu.be/7zUSU13qhvQ

    ** Please do not watch while Driving **

    In This Episode, Reggie and Robert talk about different MR Angiography techniques, with guest Matthew Hayes RT(R)(MR), Creator and President, ScanLabMR, and Professor of MRI, Adventist University of Health Sciences.

    Matthew opens by explaining the Time of Flight (TOF), and the pros and cons of each 2D and 3D Technique. Then explains contrast enhancement techniques and the importance of understanding Time to Center (TTC). He also shares a few tricks to help with missing the bolus.

    To wrap up, Matthew breaks down, Time Resolve, Phase Contrast, Velocity encoding (Venc), and the difference between Visualization and Quantification.

    Thanks for Joining Us here in Zone 3! šŸ’Æ


    Guest Links:
    ScanlabMR --- https://scanlabmr.com/
    imagingU --- https://imagingu.com/courses
    individual experience with Scanlab email them @ [email protected]


    About our Sponsor:
    Aegys is an innovative leader in the MRI safety industry and the Creator of The TechGate Automatic.
    Aegys is committed to providing innovative product and process solutions that enhance overall magnet safety and improve efficiency. TechGate Auto is a Zone 4 Barrier System that keeps patients and MRI technologists safe. TechGate Auto allows technologists to focus on the care of patients and efficient room turnaround rather than worrying about anyone entering the MRI room behind them. Easy to use and designed for the MRI environment, TechGate Auto is deployed whenever the technologist enters or leaves the MR room or via push button remote control, providing an immediate physical restriction of access to all unauthorized individuals.

    The use of a ā€œcautionā€ barrier at the entrance to the MR room is now a recommendation of the American College of Radiology MR Safety Committee.


    Links
    Aegys' Tech Gate Auto- https://aegysgroup.com/

    ----------
    Imaging Diversified

    Imaging Diversified was established in 2019 with the aspiration of offering onsite training to his peers through vendors that sell MRI and CT equipment. He received subpar training on more than one occasion after new MRI installations. With the goal to remedy this, he started being more active in sharing his knowledge on scanner utilization starting in 2011 after attending a conference by Dr. Kanal. Over years he was exposed to different vendors and learned the systems to become a superuser. He then shared that knowledge with his peers. This passion later became a business that welcomes application specialists and knowledgeable users that want to share their expertise and get paid to do it.

    Links:
    Email: [email protected]
    Website: www.imagingdiversified.com
    Social Media: Imaging Diversified

  • Watch Episode Here --> MRI Lawsuits with Expert Witness Tobias Gilk or https://youtu.be/rVSFJJa6gPo

    Once again Zone 3 Podcast is lucky to be joined by none other than Tobias Gilk. Tobias is a consultant on issues of MRI / Radiology facilities, safety, and operation, with experience in product safety specific to MR Conditional labeling and principles.

    Heā€™s spent 15+ years as a practicing architect developing particular expertise in the integration of buildings with highly technical operations and siting requirements for multi-million dollar medical imaging devices. Involved in professional and regulatory aspects of safety and design for radiology / MRI.

    Currently serving as senior vice president for RADIOLOGY-Planning, a Junk Architects' company, specializing in design for radiology, nuclear medicine, and radiation therapy facilities.

    Inherently with the challenges of maintaining a safe MRI environment, there can be safety incidents that can even lead to bodily harm. Tobias has been asked to serve as an expert witness when these cases go into litigation. Tobias talks about his experiences with this. Initially, he was asked to work with cases specific to architectural layout and how poor facility design can lead to compromised safety. But over time his requested services have expanded.

    The first or most direct example of the relationship between the MRI equipment and the building itā€™s put in is when the magnet quenches. When a magnet quenches that can cause damage to the MRI scanner and the building. Toby stresses that the risks associated with a quench can be mitigated if the facility is due diligent in proactively preventing hazards with proper facility design and construction. Inspection and constant maintenance can drastically reduce the probability of safety incidents.

    Tobias' area of expertise and experience with safety concerns evolved from initially being focused on the design of the space and how that may have led to a catastrophic event. To MRI safety practices. Specifically, facility safety policies put in place. Are they being implemented and then followed?

    When approached for expert witness consultation, this can either be from the plaintiff's side or the defense's side. Influenced by Dr. Emanuel Kanal, Tobias Gilk will first request that they donā€™t initially identify which side they're on. He asked to be presented with simply the facts. And from that, heā€™s able to review the details of the case with zero bias on either side.

    Itā€™s interesting to hear specific case examples and what the resulting investigation leads to. Tobias shares the details of these cases discussing the breakdown of how the evidence helps to expedite the conclusion. He helps to explain what and where things went wrong. What was learned from each incident and how did that lead to the implementation of more focused safety-specific policies moving forward.

    Tobias Gilk has been somewhat of a pioneer for the industry in terms of his influence on the evolution of MRI safety. Not only does he serve as an expert witness, and facility design consultant, he also works as the admin for the largest worldwide safety group of like-minded professionals with his Facebook MRI Safety group and is recognized as a major presence and MRI safety icon


    ---Links---
    Episode: MRI Facility Design - https://youtu.be/ixL9rdZJihM
    Episode: Evolution of MRI Safety - https://youtu.be/UIMe9bgmS2U
    Contact: Tobias Gilk Website - https://gilkradiologyconsultants.com/

    About our Sponsor:
    Aegys is an innovative leader in the MRI safety industry and the Creator of The TechGate Automatic.
    Aegys is committed to providing innovative product and process solutions that enhance overall magnet safety and improve efficiency. TechGate Auto is a Zone 4 Barrier System that keeps patients and MRI technologists safe. TechGate Auto allows technologists to focus on the care of patients and efficient room turnaround rather than worrying about anyone entering the MRI room behind them. Easy to use and designed for the MRI environment, TechGate Auto is deployed whenever the technologist enters or leaves the MR room or via push-button remote control, providing an immediate physical restriction of access to all unauthorized individuals.

    The use of a ā€œcautionā€ barrier at the entrance to the MR room is now a recommendation of the American College of Radiology MR Safety Committee.


    Links
    Aegys' Tech Gate Auto- https://aegysgroup.com/

    SHOW LESS

  • Check out the Video ---> Spatial Resolution: https://youtu.be/_rtqLdWvK2I
    Matt helps to describe the concept of spatial resolution in MRI terms. In MRI, spatial resolution is defined by the size of the imaging voxels. Since voxels are three-dimensional rectangular solids, the resolution is frequently different in the three different directions. The size of the voxel and therefore the resolution depends on matrix size, the field-of-view, and the slice thickness.

    Resolution is the ability of the human eyes to distinguish one structure from another. In MRI the resolution is determined by the number of pixels in a specified FOV. The higher the image resolution, the better the small pathologies can be diagnosed. Resolution is directly proportional to the number of pixels (The higher the number of pixels the greater the resolution). The pixel size can be calculated by dividing the field of view by the matrix size


    Thanks for joining us here in Zone 3! Make sure to Like and Subscribe.

    Links from Episode Discussion:
    Philips Healthcare innovation -- https://youtu.be/Z7d9xadr3VM
    Psychology of the workplace -- https://youtu.be/iJ2uFGyEakk

    About our Guest:
    Matt is the President of RITE Advantage LLC. A company focused on educating and testing MRI, CT, Sonography, and Radiography students and technologists. The lead MRI technologist and a certified MR Safety Officer at Advocate Sherman Hospital. Matt is also the MRI/CT Physics Professor at Elgin Community College.

    Mattā€™s very knowledgeable at MRI physics which is the fundamental factor for image acquisition. So in addition to tricks and tips learned from coworkers, Matt stresses the importance of understanding how to optimize the image youā€™re acquiring by means of physics. Matt appreciates the artistic influence that naturally comes with photography. If you understand whatā€™s happening on the back end in terms of k space etc., then you can be the creator of new tips and tricks to share with your coworkers and team.

    Rite Advantage - Education Platform
    Riteadvantage.com wants to help you reach your goals and have fun doing it.
    šŸ˜šŸ•³Get a discount------ https://riteadvantage.com/?ref=Zone3p...


    About our Sponsor:
    Aegys is an innovative leader in the MRI safety industry and the Creator of The TechGate Automatic.
    Aegys is committed to providing innovative product and process solutions that enhance overall magnet safety and improve efficiency. TechGate Auto is a Zone 4 Barrier System that keeps patients and MRI technologists safe. TechGate Auto allows technologists to focus on the care of patients and efficient room turnaround rather than worrying about anyone entering the MRI room behind them. Easy to use and designed for the MRI environment, TechGate Auto is deployed whenever the technologist enters or leaves the MR room or via push button remote control, providing an immediate physical restriction of access to all unauthorized individuals.

    The use of a ā€œcautionā€ barrier at the entrance to the MR room is now a recommendation of the American College of Radiology MR Safety Committee.


    Links
    Aegys' Tech Gate Auto- https://aegysgroup.com/

  • See Video -> Workplace Psychology (https://youtu.be/iJ2uFGyEakk)

    How do you approach each day of work? Are your Vibrations Highs? Do you add or Subtract from your Department? Are you constantly Complaining? Do you have Confidence? Are you Competent? Do you feel worthy?

    These are some of the questions our Guest Rob Cloutier wants us to ask ourselves and if the answer isn't what you want it to be, It is time to figure out why.

    Being a Great Technologist is more than just being able to Scan patients well. You also need to be a great Professional. Rob opens up the conversation by discussing the Inferior superior game that we all get caught up in. Were the Radiologist is top and the technologist is Mid-level. Rob Stress how detrimental this way of thinking is to our common goal of patient care and that if we can begin to feel confident, competent, and worthy we can break this mold.

    Rob then discusses the difficulty he has had with teaching professionalism and what he has learned along the way. Rob has taken a lot of advice from Bill Wiersma and his book "The Power of Professionalism" and is mentioned in Bill Wiersma's 'Power of Identity" book.

    Towards the End of our discussion, Rob discusses his experience getting his MRSO cert and what he took away from that trip. He also discusses his New SMIL Radiology Collab Education training Program for Crosstraining technologists.

    Thanks for joining us here in Zone 3! Remember to Subscribe and Like the video if it was helpful.

  • Check out the Video ---> MRI Tips and Tricks: From MRI Image Optimization to Claustrophobic Patients

    MRI sequence optimization can be a daunting task for new technologists. In this episode of Zone 3 Podcast, Matt Rederer from RITE Advantage LLC joins Reggie and Robert to share some tips on optimizing Image Contrast, image quality, scan time, and many parameters that might come up when it comes to being an "MRI artist."

    Whether the topic was dealing with claustrophobic patients or just providing some general guidance in life as one who performs these examinations every day - there was plenty of insight shared by Matt's experiences and knowledge!

    About our Guest:
    Matt is the President of RITE Advantage LLC. A company focused on educating and testing MRI, CT, Sonography, and Radiography students and technologists. The lead MRI technologist and a certified MR Safety Officer at Advocate Sherman Hospital. Matt is also the MRI/CT Physics Professor at Elgin Community College.

    Mattā€™s very knowledgeable at MRI physics which is the fundamental factor for image acquisition. So in addition to tricks and tips learned from coworkers, Matt stresses the importance of understanding how to optimize the image youā€™re acquiring by means of physics. Matt appreciates the artistic influence that naturally comes with photography. If you understand whatā€™s happening on the back end in terms of k space etc., then you can be the creator of new tips and tricks to share with your coworkers and team.

    Rite Advantage - Education Platform
    Riteadvantage.com wants to help you reach your goals and have fun doing it.
    šŸ˜šŸ•³Get a discount------ https://riteadvantage.com/?ref=Zone3podcast


    About our Sponsor:
    Aegys is an innovative leader in the MRI safety industry and the Creator of The TechGate Automatic.
    Aegys is committed to providing innovative product and process solutions that enhance overall magnet safety and improve efficiency. TechGate Auto is a Zone 4 Barrier System that keeps patients and MRI technologists safe. TechGate Auto allows technologists to focus on the care of patients and efficient room turnaround rather than worrying about anyone entering the MRI room behind them. Easy to use and designed for the MRI environment, TechGate Auto is deployed whenever the technologist enters or leaves the MR room or via push-button remote control, providing an immediate physical restriction of access to all unauthorized individuals.

    The use of a ā€œcautionā€ barrier at the entrance to the MR room is now a recommendation of the American College of Radiology MR Safety Committee.


    Links
    Aegys' Tech Gate Auto- https://aegysgroup.com/

  • See Episode Video ---> Travel MR Episode

    Johnny Munster R.T.(R)(CT)(MR)(ARRT) stopped by the Zone3Podcast studio to discuss how lucrative the field of Travel MRI currently is. As detailed in the episode, due to a shortage in nationwide staffing there has been monetary incentives put in place to recruit MRI technologist to consider MRI travel assignments. These assignments range in duration but typically last 13 weeks at a time. With opportunities to extend their contract.

    Johnny advises that there are different travel agencies. And to be sure to do your due diligence when considering both an agency and an assignment location. Johnny stresses the importance of researching any potential travel assignment locations housing cost. As they may be a reason to not consider a location. If the finances provided donā€™t adequately account for the cost of living in the area it would not be in your best interest to accept.

    Itā€™s fun to hear the excitement and joy Johnny has gotten out of his travel experience so far. Heā€™s had some memorable assignments. Ranging from less desirable to ā€œdonā€™t wanna leaveā€. Heā€™s enjoyed the local culture and the best of what each place has to offer. He encourages any other techs to do the same. Heā€™s loved the places and the people heā€™s met along the way. And the friendships heā€™s made.

  • Check it out on YT ---> 2021 Wrap up and RSNA Take ways!

    In this quick episode of Zone 3 Podcast, Robert and Reggie Review their Takeaways from RSNA 2021 and Hint at some of their projects that will be released in 2022.

    MR Arcade --> Coming
    MRI Job Listing --> Coming
    MRI Animated Series --> Coming

    Keep up to date with our Ongoing project @ Zone3podcast.com

    Thank you all for all your Support. 2022 is going to be a great year. Stay tuned.

    About our Sponsor:
    Aegys is an innovative leader in the MRI safety industry and the Creator of The TechGate Automatic.
    Aegys is committed to providing innovative product and process solutions that enhance overall magnet safety and improve efficiency. TechGate Auto is a Zone 4 Barrier System that keeps patients and MRI technologists safe. TechGate Auto allows technologists to focus on the care of patients and efficient room turnaround rather than worrying about anyone entering the MRI room behind them. Easy to use and designed for the MRI environment, TechGate Auto is deployed whenever the technologist enters or leaves the MR room or via push-button remote control, providing an immediate physical restriction of access to all unauthorized individuals.

    The use of a ā€œcautionā€ barrier at the entrance to the MR room is now a recommendation of the American College of Radiology MR Safety Committee.

    Links
    Aegys' Tech Gate Auto- https://aegysgroup.com/

  • Watch on YouTube --> FDA's Role in the Off Label Use

    In this episode of Zone 3 Podcast, we are lucky to have returning guest Emanuel Kanal, MD, FACR, FISMRM, MRMD, MRSE, AANG. Chief, Division of Emergency Radiology and Teleradiology. Director, Magnetic Resonance Services. Professor of Radiology and Neuroradiology. Department of Radiology University of Pittsburgh Medical Center, here to discuss the FDA's role.
    Specifically, how the FDA only governs who can market in the US, not how MD should practice medicine.

    He also discusses how off-label use should be the standard if that is what is best for the patient regardless of FDA approval. Dr. Kanal helps to explain this by discussing an example about the neonate formula.

    He urges viewers to understand FDAā€™s approval regarding MRI safety is only to those companies who find it beneficial(profitable) to get FDA approval. He also talks about the FDA approval process and how the safety guidelines are created. He takes us through many dates on how the FDA came to be, reminding us of the big picture of the FDA's role as a federal regulator.

    Toward the end, Dr. Kanal discusses his passion for flying. As a licensed pilot, Dr. Kanal tries to find the time in his busy schedule. It was fun to sit down with Dr. Kanal and see and hear that passion when spoke to him about something other than Diagnostic imaging.

    Thanks for Joining Us here in Zone 3.

    Timestamps below
    00:00 intro
    00:54 Dr. Kanal Intro
    26:47 FDA's Role and Why they don't have oversight over how MD practice Medicine
    51:00 -Liability when going off Label
    1:20:45 Message to Technologist
    1:28:51 Community Questions
    1:50:19 Outro with Sponsor popup

    About our Sponsor:
    Aegys is an innovative leader in the MRI safety industry and the Creator of The TechGate Automatic.
    Aegys is committed to providing innovative product and process solutions that enhance overall magnet safety and improve efficiency. TechGate Auto is a Zone 4 Barrier System that keeps patients and MRI technologists safe. TechGate Auto allows technologists to focus on the care of patients and efficient room turnaround rather than worrying about anyone entering the MRI room behind them. Easy to use and designed for the MRI environment, TechGate Auto is deployed whenever the technologist enters or leaves the MR room or via push-button remote control, providing an immediate physical restriction of access to all unauthorized individuals.

    The use of a ā€œcautionā€ barrier at the entrance to the MR room is now a recommendation of the American College of Radiology MR Safety Committee.


    Links
    Aegys' Tech Gate Auto- https://aegysgroup.com/
    Questions Link- https://community.imagingqa.com/

  • Check it out on Youtube --> HERE https://youtu.be/Z7d9xadr3VM

    In this Zone 3 Podcast Clip of RSNA 2021 Reggie and Robert hang out in the Philips booth with Margriet Nijrens, Head of MR Marketing. Margriet and Reggie Discuss Philips new 1.5T MR 5300 the next revolution in helium-free MR operations, MR Workspace, SmartSpeed which utilizes our state-of-the-art speed engine Compressed SENSE, and an award-winning AI reconstruction technology and their Pediatric Coaching app.


    New 1.5T MR 5300
    MR 5300 is the next revolution in helium-free MR operations. Ramp up your productivity to meet the growing demand for exceptional quality images. This innovative 1.5T MR system, powered by AI1 technology, simplifies and automates the most complex clinical and operational tasks. So you can focus on what matters the most: your patients.


    MR Workspace
    MR Workspace is our industry-unique control room engine that delivers quality and efficiency without compromise. This intuitive solution is designed to simplify the path from image acquisition to diagnosis and to empower your team to drive productivity and predictability for a smooth-running department.


    Philips SmartSpeed*
    SmartSpeed is the next-generation fast imaging technology that delivers speed and image quality without compromise. It utilizes our state-of-the-art speed engine Compressed SENSE and an award-winning AI reconstruction technology delivered at the source of the MR signal to ensure no data loss.

    Pediatric Coaching
    Pediatric Coaching, a holistic solution designed to be a less stressful experience for parents and their children undergoing MRI scans. Using gamification and ā€˜buddy systemā€™ techniques to prepare children and their parents beforehand, the solution helps guide young children through the MRI procedure to significantly enhance the patient experience.

    Thanks for Joining us here in Zone 3.


    Philips Links : https://www.usa.philips.com/healthcare/resources/landing/mri-innovations

    About our Sponsor:
    Aegys is an innovative leader in the MRI safety industry and the Creator of The TechGate Automatic.
    Aegys is committed to providing innovative product and process solutions that enhance overall magnet safety and improve efficiency. TechGate Auto is a Zone 4 Barrier System that keeps patients and MRI technologists safe. TechGate Auto allows technologists to focus on the care of patients and efficient room turnaround rather than worrying about anyone entering the MRI room behind them. Easy to use and designed for the MRI environment, TechGate Auto is deployed whenever the technologist enters or leaves the MR room or via push button remote control, providing an immediate physical restriction of access to all unauthorized individuals.

    The use of a ā€œcautionā€ barrier at the entrance to the MR room is now a recommendation of the American College of Radiology MR Safety Committee.


    Links
    Aegys' Tech Gate Auto- https://aegysgroup.com/